Giant(10-200K)
•Online double-conversion •DSP technology guarantees high reliability •True galvanic isolation transformer design •Control designed to withstand all kinds of loads •Intelligent battery management to prolong battery lifecycle •Independent ventilation enhance durable operation under harsh environment •Adjustable battery numbers •Accept dual-mains input •Parallel operation with up to 4 units (option) •Variety of communication options available •Reverse phase frequency operation and supports non-neutral input
所属分类:
定制化UPS电源
产品描述
•Online double-conversion
•DSP technology guarantees high reliability
•True galvanic isolation transformer design
•Control designed to withstand all kinds of loads
•Intelligent battery management to prolong battery lifecycle
•Independent ventilation enhance durable operation under harsh environment
•Adjustable battery numbers
•Accept dual-mains input
•Parallel operation with up to 4 units (option)
•Variety of communication options available
•Reverse phase frequency operation and supports non-neutral input
MODEL | Giant 10K | Giant 15K | Giant 20K | Giant 30K | Giant 40K | Giant 60K | Giant 80K | Giant 100K | Giant 120K | Giant 160K | Giant 200K | ||
CAPACITY | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | 100KVA/80KW | 120KVA/96KW | 160KVA/128KW | 200KVA/160KW | ||
INPUT | |||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph + N) | ||||||||||||
Acceptable Voltage Range | 165VAC ~ 280VAC (Ph-N) 285VAC ~ 485VAC (Ph-Ph) |
||||||||||||
Frequency | 50/60 Hz ± 10 % | ||||||||||||
INVERTER | |||||||||||||
Nominal Voltage | 3 x 380VAC/400VAC/415VAC (3Ph + N) | ||||||||||||
Precision | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
||||||||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
||||||||||||
Max. Synchronisation Speed | ±1 Hz/s | ||||||||||||
Waveform | Pure Sinewave | ||||||||||||
Total Harmonic Distortion (THDv) | <2% (Linear Load) <5% (Non-linear Load) |
||||||||||||
Phase Displacement | 120º ±1% (balanced load) 120º ±2% (imbalances 50% of the load) |
||||||||||||
Dynamic Recovery Time | 3 cycles at 90 % of the static value | ||||||||||||
Admissible Overload | 110% ~ 150% 10 min ~ 60 sec 150% ~ 160% 60 sec~ 200ms >160% 200ms |
||||||||||||
Admissible Crest Factor | 3:1 | ||||||||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | ||||||||||||
Imbalance Output Voltage @ 100% Unbalanced Load | <1% | ||||||||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
||||||||||||
STATIC BYPASS | |||||||||||||
Type | Solid state | ||||||||||||
Voltage | 176VAC ~ 264VAC (Ph-N) 304VAC ~ 456VAC (Ph-Ph) |
||||||||||||
Frequency | 50/60 Hz ± 10 % | ||||||||||||
Activation Criterion | Microprocessor control | ||||||||||||
Transfer Time | Zero | ||||||||||||
Admissible Overload | 0% ~ 150% continuous working 150% ~ 180% 60 min~5 min >180% 5 min |
||||||||||||
Transfer to Bypass | Immediate, for overloads above 160% | ||||||||||||
Retransfer | Automatic after alarm clear | ||||||||||||
MAINTENANCE BYPASS | |||||||||||||
Type | Without interruption | ||||||||||||
Voltage | Same as the bypass input | ||||||||||||
Frequency | Same as the bypass input | ||||||||||||
Overall Efficiency | Line Mode | 89% | 90% | 91% | 92% | ||||||||
Battery Mode | 90% | 91% | 92% | 93% | |||||||||
BATTERY & CHARGER | |||||||||||||
Battery Type and Numbers | 12VDC x 32 pcs (29~32 pcs adjustable) | ||||||||||||
Nominal Battery Voltage | 384 VDC (Based on 32pcs batteries) | ||||||||||||
Charging Method | CC/CV | ||||||||||||
Precision | ±1% | ||||||||||||
Charging Current | Default 10A, *Maximum=Capacity(KW)/Battery Voltage(real-time). | Default 10A; Maximum 40A; 5A@ full load | |||||||||||
Charging Voltage | 432 VDC (Based on 32pcs batteries) | ||||||||||||
PHYSICAL | |||||||||||||
Dimensions, D x W x H(mm) | 656 x 405 x 817 | 656 x 405 x 941 | 821 x 432 x 1159 | 975 x 554 x 1286 | 975 x 635 x 1326 | 1051x705x1646 | |||||||
Net Weight (Kgs) | 118 | 120 | 145 | 193 | 278 | 365 | 471 | 573 | 650 | 735 | 790 |
* The maximum current is never higher than 40A.